Middle flange bolt tensile stress verification per Practical Valve Design Manual Table 5-112.
Input Parameters
Gasket Mean Diameter DDP
mm
Calculation Pressure P
MPa
Gasket Width bDP
mm
Gasket Factor mDP
Elasticity Coefficient η
Seating Pre-Stress qYJ
MPa
Gasket Shape Factor KDP
Effective Gasket Width BN
mm
Bolt Count Z
Single Bolt Area S1
mm²
Allowable Tensile Stress [σL]
MPa
Calculate
Results
Medium Force QDJ
N
—
Sealing Force QDF
N
—
Elastic Force QDT
N
—
Operating Force Q'
N
—
Preload Force Q''
N
—
Design Load QL
N
—
Total Bolt Area SL
mm²
—
Bolt Stress σL
MPa
—
ASME II-D: [σL] ≥ σL
—